CNS: Difference between revisions

From CCP4 wiki
Jump to navigation Jump to search
mNo edit summary
No edit summary
 
(4 intermediate revisions by 2 users not shown)
Line 3: Line 3:
Among its capabilities is simulated annealing molecular dynamics refinement.
Among its capabilities is simulated annealing molecular dynamics refinement.


* [http://cns-online.org/v1.2/ CNS home page]
* [http://cns-online.org/v1.3/ CNS home page] and [http://cns-online.org/wiki/index.php/Main_Page wiki]


Consider also the more automated and user-friendly [[PHENIX]] which, although less complete, is under more active development.
There is a parallelization (OpenMP) source code patch for CNS from Kay dot Diederichs at uni-konstanz dot de. It is now distributed with CNS 1.2 as an alternate download. The parallel version  features (roughly) a 2-fold speedup on a 4-core machine for a typical simulated annealing omit map run.
 
Joe Krahn is working an RPM spec for installing CNS on Linux, which includes standard and OpenMP build versions, and is also experimenting with using the CCP4i GUI to run CNS. If interested, [[User_Talk:joekrahn|leave  him a message]].
 
 
== Troubleshooting ==
 
 
It was reported that due to an operating system bug in Mac OSX 10.5.x, the program may crash with
 
forrtl: severe (174): SIGSEGV, segmentation fault occurred
Image              PC        Routine            Line        Source           
cns_solve          003548DF  Unknown              Unknown  Unknown
cns_solve          00339FBB  Unknown              Unknown  Unknown
cns_solve          000F62EC  Unknown              Unknown  Unknown
Stack trace terminated abnormally.
 
This may occur if you are running the program with input redirection, but without output redirection, i.e.,
 
cns < test.inp
 
and the input file contains one ore more blank lines.
 
As a possible remedy, try:
 
cns < test.inp > test.out
 
 
== Super-resolution and DEN ==
 
"Super-resolution" was defined in the DEN paper as
achieving coordinate accuracy better than the resolution
limit d_min of the diffraction data.  This
definition was proposed in analogy to its wide-spread use in optical microscopy:
"super-resolution" methods such as STORM, PALM, and STED achieve
accuracy of positions of fluorescent labels significantly better than the
diffraction limit (in some cases, sub-nanometer accuracy  -
Pertsinidis, Zhang, Chu, Nature 466, 647-651, 2010). 
 
DEN was found to be useful to move some atoms into correct
positions in cases where electron density maps are difficult or
impossible to interpret at low resolution. By default, DEN is
active during the first torsion angle molecular dynamics stages,
but then turned off during the last two stages.  In addition, the
DEN network is deformable. Thus, DEN is very different from
"secondary structure" restraints or point restraints to reference
models which are "on" all the time.  Rather, DEN steers or
guides the torsion angle conformational search process during
refinement.
 
 
== Selected references ==
 
* [http://cns-online.org/v1.3/about_cns/jn0043.pdf A.T. Brunger, P.D. Adams, G.M. Clore, P.Gros, R.W. Grosse-Kunstleve, J.-S. Jiang, J. Kuszewski, N. Nilges, N.S. Pannu, R.J. Read, L.M. Rice, T. Simonson, G.L. Warren,Crystallography & NMR System (CNS), A new software suite for macromolecular structure determination, Acta Cryst.D54, 905-921(1998).]
* [http://cns-online.org/v1.3/about_cns/brunger_nature_protocols_2007.pdf A.T. Brunger, Version 1.2 of the Crystallography and NMR System, Nature Protocols 2, 2728-2733 (2007).]
* [http://dx.doi.org/10.1038/nature08892 G.F. Schroeder, M. Levitt, and A.T. Brunger, Super-resolution biomolecular crystallography with low-resolution data, Nature 464, 1218-1222, 2010]

Latest revision as of 13:47, 29 December 2010

CNS stands for "Crystallography and NMR System" and is an integrated and full-featured program for the determination and refinement of X-ray crystallographic and NMR structures.

Among its capabilities is simulated annealing molecular dynamics refinement.

There is a parallelization (OpenMP) source code patch for CNS from Kay dot Diederichs at uni-konstanz dot de. It is now distributed with CNS 1.2 as an alternate download. The parallel version features (roughly) a 2-fold speedup on a 4-core machine for a typical simulated annealing omit map run.

Joe Krahn is working an RPM spec for installing CNS on Linux, which includes standard and OpenMP build versions, and is also experimenting with using the CCP4i GUI to run CNS. If interested, leave him a message.


Troubleshooting[edit | edit source]

It was reported that due to an operating system bug in Mac OSX 10.5.x, the program may crash with

forrtl: severe (174): SIGSEGV, segmentation fault occurred
Image              PC        Routine            Line        Source             
cns_solve          003548DF  Unknown               Unknown  Unknown
cns_solve          00339FBB  Unknown               Unknown  Unknown
cns_solve          000F62EC  Unknown               Unknown  Unknown

Stack trace terminated abnormally.

This may occur if you are running the program with input redirection, but without output redirection, i.e.,

cns < test.inp

and the input file contains one ore more blank lines.

As a possible remedy, try:

cns < test.inp > test.out


Super-resolution and DEN[edit | edit source]

"Super-resolution" was defined in the DEN paper as achieving coordinate accuracy better than the resolution limit d_min of the diffraction data. This definition was proposed in analogy to its wide-spread use in optical microscopy: "super-resolution" methods such as STORM, PALM, and STED achieve accuracy of positions of fluorescent labels significantly better than the diffraction limit (in some cases, sub-nanometer accuracy - Pertsinidis, Zhang, Chu, Nature 466, 647-651, 2010).

DEN was found to be useful to move some atoms into correct positions in cases where electron density maps are difficult or impossible to interpret at low resolution. By default, DEN is active during the first torsion angle molecular dynamics stages, but then turned off during the last two stages. In addition, the DEN network is deformable. Thus, DEN is very different from "secondary structure" restraints or point restraints to reference models which are "on" all the time. Rather, DEN steers or guides the torsion angle conformational search process during refinement.


Selected references[edit | edit source]