CC1/2

From CCP4 wiki
Revision as of 09:27, 23 April 2016 by Kay (talk | contribs) (Created page with "Examples for citations from papers using (possibly among other criteria) CC<sub>1/2</sub> and/or the paired refinement method (reference below) for finding the high-resolution...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

Examples for citations from papers using (possibly among other criteria) CC1/2 and/or the paired refinement method (reference below) for finding the high-resolution cutoff.

  1. "In choosing our highest-resolution cutoff we chose shells, which still fulfil CC1/2 (ref. 57) >25% and I/σ(I)greater than or equal to 0.5 and which were supported by our results from the paired refinement method (ref. 57). Choosing a lower resolution cutoff did not improve the overall quality of the maps." Models were refined at 6.0 and 3.4 Å, respectively [1].


References

P.A. Karplus and K. Diederichs (2012) Linking Crystallographic Model and Data Quality. Science 336, 1030-1033