Mtz2hkl: Difference between revisions

Jump to navigation Jump to search
11 bytes added ,  18 December 2020
no edit summary
 
No edit summary
 
(One intermediate revision by the same user not shown)
Line 1: Line 1:
[http://shelx.uni-ac.gwdg.de/~tg/mtz2x/mtz2hkl/mtz2hkl.php mtzhkl] can be used to convert [[file-formats#mtz| mtz]]-files to [[file-formats#hkl | hkl]]-format suitable for input to [[SHELXL]]. The program attempts to guess all required information from the [[file-formats#mtz| mtz]]-file in order to minimise user interaction. So simply typing
[https://homepage.univie.ac.at/tim.gruene/research/programs/conv/mtz2x/mtz2hkl/index.php mtzhkl] can be used to convert [[file-formats#mtz| mtz]]-files to [[file-formats#hkl | hkl]]-format suitable for input to [[SHELXL]]. The program attempts to guess all required information from the [[file-formats#mtz| mtz]]-file in order to minimise user interaction. So simply typing
  mtz2hkl mydata.mtz
  mtz2hkl mydata.mtz
creates a file mydata.hkl suitable for input to [[SHELXL]].
creates a file mydata.hkl suitable for input to [[SHELXL]].
Line 5: Line 5:
If not all information could be uniquely determined from the mtz-file (e.g. because several data columns are present), the program prints short usage instructions and exits.
If not all information could be uniquely determined from the mtz-file (e.g. because several data columns are present), the program prints short usage instructions and exits.


While [[CCP4]] programs usually use amplitudes, [[SHELXL]] refines against either intensities or amplitudes. It is recommended to use intensities and therefore one should make sure the conversion from intensities to amplitudes (often done with [[truncate]]) keeps the original intensities in the output [[file-formats#mtz|mtz]-file.
While [[CCP4]] programs usually use amplitudes, [[SHELXL]] refines against either intensities or amplitudes. It is recommended to use intensities and therefore one should make sure the conversion from intensities to amplitudes (often done with [[truncate]]) keeps the original intensities in the output .mtz file.


If this is not the case, the option '-2' in mtz2hkl converts amplitudes back to intensities by squaring the amplitudes and converting the standard deviations according to <math>\sigma_{I} = 2|F|\sigma_{F} = |\frac{\partial I}{\partial F}| \sigma_{F}</math>.
If this is not the case, the option '-2' in mtz2hkl converts amplitudes back to intensities by squaring the amplitudes and converting the standard deviations according to <math>\sigma_{I} = 2|F|\sigma_{F} = |\frac{\partial I}{\partial F}| \sigma_{F}</math>.
1,328

edits

Cookies help us deliver our services. By using our services, you agree to our use of cookies.

Navigation menu