Quality Control: Difference between revisions

Line 9: Line 9:
Reference: Köhler, R., Schäfer, K., Müller, S., Vignon, G., Diederichs, K., Philippsen, A., Ringler, P., Pugsley, A.P., Engel, A., Welte, W. (2004) Structure and assembly of the pseudopilin PulG. ''Molecular Microbiology'' '''54''', 647-664.
Reference: Köhler, R., Schäfer, K., Müller, S., Vignon, G., Diederichs, K., Philippsen, A., Ringler, P., Pugsley, A.P., Engel, A., Welte, W. (2004) Structure and assembly of the pseudopilin PulG. ''Molecular Microbiology'' '''54''', 647-664.
[http://dx.doi.org/10.1111/j.1365-2958.2004.04307.x]
[http://dx.doi.org/10.1111/j.1365-2958.2004.04307.x]
=== XDS.INP for remote high data ===
JOB=XYCORR INIT COLSPOT IDXREF DEFPIX INTEGRATE CORRECT
! for this experiment:
ORGX=1031 ORGY=1001
DETECTOR_DISTANCE=220
OSCILLATION_RANGE=1
X-RAY_WAVELENGTH=0.97857
NAME_TEMPLATE_OF_DATA_FRAMES=images/pulg_semet_D22_2_???.img DIRECT  TIFF
DATA_RANGE=5 124
SPOT_RANGE=5 124
SPACE_GROUP_NUMBER=179
UNIT_CELL_CONSTANTS= 85.5  85.5  145.2  90 90 120
FRIEDEL'S_LAW=FALSE
STRICT_ABSORPTION_CORRECTION=TRUE
! parameters with changes wrt default values:
VALUE_RANGE_FOR_TRUSTED_DETECTOR_PIXELS=8000. 30000.
MINIMUM_ZETA=0.05
INCLUDE_RESOLUTION_RANGE=50 0
STRONG_PIXEL=6
BACKGROUND_RANGE=1 10
! parameters specifically for this detector and beamline:
NX=2048 NY=2048 QX=0.079092  QY=0.079092  !MARCCD 165mm version
DETECTOR=CCDCHESS        MINIMUM_VALID_PIXEL_VALUE=0    OVERLOAD=65000
DIRECTION_OF_DETECTOR_X-AXIS=1 0 0
DIRECTION_OF_DETECTOR_Y-AXIS=0 1 0
INCIDENT_BEAM_DIRECTION=0 0 1
ROTATION_AXIS=1 0 0
FRACTION_OF_POLARIZATION=0.99
POLARIZATION_PLANE_NORMAL=0 1 0
=== XDS.INP for inflection point data ===
same as above, except
X-RAY_WAVELENGTH=0.97972
NAME_TEMPLATE_OF_DATA_FRAMES=images/pulg_semet_D22_3_???.img DIRECT  TIFF
DATA_RANGE=1 120
SPOT_RANGE=1 120