The structure is [http://www.rcsb.org/pdb/explore/explore.do?structureId=1Y13 deposited] in the PDB, solved with SAD and refined at a resolution of 2.2 A in spacegroup P4(3)2(1)2 (#96).
The structure is [http://www.rcsb.org/pdb/explore/explore.do?structureId=1Y13 deposited] in the PDB, solved with SAD and refined at a resolution of 2.2 A in spacegroup P4(3)2(1)2 (#96).
The data for this project were provided by Jürgen Bosch (SGPP) and are linked to [http://bl831.als.lbl.gov/example_data_sets/ACA2011/DPWTP-website/index.html the ACA 2011 workshop website] and [ftp://turn5.biologie.uni-konstanz.de/pub/xds-datared/1y13/ here].  
The data for this project were provided by Jürgen Bosch (SGPP) and are linked to [http://bl831.als.lbl.gov/example_data_sets/ACA2011/DPWTP-website/index.html the ACA 2011 workshop website] and [https://{{SERVERNAME}}/pub/xds-datared/1y13/ here].  
There are two high-resolution (2 Å) datasets E1 (wavelength 0.9794Å) and E2 (@ 0.9174Å) collected (with 0.25° increments) at an ALS beamline on June 27, 2004, and a weaker dataset collected earlier at a SSRL beamline. We will only use the former two datasets here.
There are two high-resolution (2 Å) datasets E1 (wavelength 0.9794Å) and E2 (@ 0.9174Å) collected (with 0.25° increments) at an ALS beamline on June 27, 2004, and a weaker dataset collected earlier at a SSRL beamline. We will only use the former two datasets here.


Line 229: Line 229:
thus proving that both datasets were interrupted for 20 minutes around frame 370.
thus proving that both datasets were interrupted for 20 minutes around frame 370.


Interestingly, both datasets appear to be collected at the same time, but at different wavelengths (E1 at 0.9794 Å, E2 at 0.9184 Å), and yet the individual parts merge as follows: using the following [[XSCALE.INP]]:
Interestingly, both datasets appear to be collected at the same time, but at different wavelengths (E1 at 0.9794 Å, E2 at 0.9184 Å), and yet the individual parts merge as follows: using the following XSCALE.INP:
  UNIT_CELL_CONSTANTS=103.316  103.316  131.456  90.000  90.000  90.000
  UNIT_CELL_CONSTANTS=103.316  103.316  131.456  90.000  90.000  90.000
  SPACE_GROUP_NUMBER=96
  SPACE_GROUP_NUMBER=96