Space group determination: Difference between revisions

m
Line 30: Line 30:


The current version makes no attempt to find out about screw axes. It is assumed that the user checks the table in CORRECT.LP entitled "REFLECTIONS OF TYPE H,0,0  0,K,0  0,0,L OR EXPECTED TO BE ABSENT (*)", and identifies whether the intensities follow the rules
The current version makes no attempt to find out about screw axes. It is assumed that the user checks the table in CORRECT.LP entitled "REFLECTIONS OF TYPE H,0,0  0,K,0  0,0,L OR EXPECTED TO BE ABSENT (*)", and identifies whether the intensities follow the rules
# a two-fold screw axis along an axis in reciprocal space (theoretically) results in zero intensity for the odd-numbered (e.g., K = 2*n + 1) reflections.
# a two-fold screw axis along an axis in reciprocal space (theoretically) results in zero intensity for the odd-numbered (e.g. 0,K,0 with K = 2*n + 1) reflections, leaving the reflections of type 2*n as candidates for medium to strong reflections (they don't ''have'' to be strong, but they ''may'' be strong!).
# similarly, a three-fold screw axis (theoretically) results in zero intensity for the reflections of type 3*n+1 and 3*n+2, leaving the 3*n reflections as candidates for medium to strong reflections (they don't ''have'' to be strong, but they ''may'' be strong!).
# similarly, a three-fold screw axis (theoretically) results in zero intensity for the reflections of type 3*n+1 and 3*n+2, and allows possibly strong 3*n reflections . 3<sub>1</sub> and 3<sub>2</sub> cannot be distinguished.  
# analogously for four-fold and six-fold axes.
# analogously for four-fold and six-fold axes.
Once screw axes have been deduced from the patterns of intensities along H,0,0  0,K,0  0,0,L , the resulting space group should be identified in the lists of space group numbers printed in IDXREF.LP and CORRECT.LP, and the CORRECT step can be re-run. Those reflections that should theoretically have zero intensity are then marked with a "*" in the table. In practice, they should be (hopefully quite) weak, or even negative.
Once screw axes have been deduced from the patterns of intensities along H,0,0  0,K,0  0,0,L , the resulting space group should be identified in the lists of space group numbers printed in IDXREF.LP and CORRECT.LP, and the CORRECT step can be re-run. Those reflections that should theoretically have zero intensity are then marked with a "*" in the table. In practice, they should be (hopefully quite) weak, or even negative.