A good idea if refinement is done at low resolution but a high resolution model is available.
A good idea if refinement is done at low resolution but a high resolution model is available.


  phenix.refine data.hkl model.pdb main.reference_model_restraints=True reference_model.file=reference.pdb
  phenix.refine data.hkl model.pdb main.reference_model_restraints=True \
              reference_model.file=reference.pdb


Use reference_model.sigma=0.5 to tighten the restraints (default 1.0 Angstrom), and use reference_model.limit=30 to enlarge the limit (default 15 degrees) up to which the reference torsion angle will be used.
Use reference_model.sigma=0.5 to tighten the restraints (default 1.0 Angstrom), and use reference_model.limit=30 to enlarge the limit (default 15 degrees) up to which the reference torsion angle will be used.