Line 23: | Line 23: | ||
Second method: if you feel you would rather like to find ORGX, ORGY by smart trial-and-error, then you just need to realize that in the output of IDXREF.LP you can check the lines | Second method: if you feel you would rather like to find ORGX, ORGY by smart trial-and-error, then you just need to realize that in the output of IDXREF.LP you can check the lines | ||
DETECTOR COORDINATES (PIXELS) OF DIRECT BEAM 361.92 533.30 ! | DETECTOR COORDINATES (PIXELS) OF DIRECT BEAM 361.92 533.30 ! should be close to XDS-Viewer findings | ||
DETECTOR ORIGIN (PIXELS) AT 512.37 533.63 ! | DETECTOR ORIGIN (PIXELS) AT 512.37 533.63 ! should be close to specified ORGX, ORGY | ||
i.e. you have to change ORGX, ORGY in XDS.INP to make the upper line show the values you expect from clicking the direct beam position in XDS-Viewer. | i.e. you have to ''change ORGX, ORGY in XDS.INP to make the upper line show the values you expect'' from clicking the direct beam position in XDS-Viewer. |