Generate XDS.INP: Difference between revisions

Jump to navigation Jump to search
→‎The script: take away POSITION from REFINE(CORRECT) if electron diffraction data
(→‎The script: take away POSITION from REFINE(CORRECT) if electron diffraction data)
Line 175: Line 175:
SEPMIN=7.0
SEPMIN=7.0
CLUSTER_RADIUS=3.5
CLUSTER_RADIUS=3.5
REFINE_CORRECT="CELL BEAM ORIENTATION AXIS POSITION ! Default is: refine everything"


dname=`echo "$1" | xargs dirname`
dname=`echo "$1" | xargs dirname`
Line 500: Line 501:
   echo --- For TIMEPIX detector, please fix ROTATION_AXIS yourself!
   echo --- For TIMEPIX detector, please fix ROTATION_AXIS yourself!
   DIRECTION_OF_DETECTOR_X_AXIS="1 0 0"  
   DIRECTION_OF_DETECTOR_X_AXIS="1 0 0"  
  REFINE_CORRECT="ORIENTATION CELL AXIS BEAM ! for ED, no POSITION when CELL is refined"


elif [ "$DET" == "pilatus" ]; then
elif [ "$DET" == "pilatus" ]; then
Line 962: Line 964:
! however, if the spots from COLSPOT extend to 2A then POSITION could, and if 1.5A POSITION should be refined
! however, if the spots from COLSPOT extend to 2A then POSITION could, and if 1.5A POSITION should be refined
REFINE(IDXREF)=CELL BEAM ORIENTATION AXIS  ! add POSITION if high resolution, or DETECTOR_DISTANCE inaccurate
REFINE(IDXREF)=CELL BEAM ORIENTATION AXIS  ! add POSITION if high resolution, or DETECTOR_DISTANCE inaccurate
REFINE(INTEGRATE)= POSITION BEAM ORIENTATION ! AXIS CELL . If 1.5A or higher it is ok to refine CELL
REFINE(INTEGRATE)= POSITION BEAM ORIENTATION ! AXIS CELL . If 1.5A or higher it is ok to refine CELL (unless electron diffraction)
! REFINE(CORRECT)=CELL BEAM ORIENTATION AXIS POSITION ! Default is: refine everything
REFINE(CORRECT)= $REFINE_CORRECT
 
! parameters specifically for this detector and beamline:
! parameters specifically for this detector and beamline:
DETECTOR= $DETECTOR
DETECTOR= $DETECTOR
2,684

edits

Cookies help us deliver our services. By using our services, you agree to our use of cookies.

Navigation menu