Line 71: | Line 71: | ||
=== why do the latest XDS/XSCALE versions only give a single table, with I/sigma>=-3 cutoff? === | === why do the latest XDS/XSCALE versions only give a single table, with I/sigma>=-3 cutoff? === | ||
This was changed in the May 2010 version | This was changed in the May 2010 version. There is no keyword to get the old version of the tables back. | ||
Short explanation: the reason why this has been changed is that only the Signal/noise>=-3 table is meaningful because it describes the data that are used "downstream" for structure solution, and refinement. These are also the numbers that should go into "Table 1" of your paper. The -3*sigma cutoff is used to ensure that strongly negative intensities - which of course should not exist - do not enter downstream steps. | |||
If only | Longer explanation: the -3 sigma cutoff is actually imposed by [[XDSCONV]], not by [[XDS]] (which is why XDS_ASCII.HKL may also contain intensities that are below -3*sigma). [[XDSCONV]] performs the conversion from intensities to amplitudes (like TRUNCATE, it implements French G.S. and Wilson K.S. Acta. Cryst. (1978), A34, 517-525.). If e.g. only positive intensities were written out by XDS, and used by XDSCONV, then this would lead to wrong average intensities at high resolution, wrong conversion to amplitudes, wrong Wilson B factors, and ultimately to worse models. | ||
Would it matter if the cutoff were not -3, but e.g. -4? Simple statistics can tell us what the percentage of reflections with intensity < -3*sigma is in a resolution shell that contains only noise (i.e. far beyond the useful resolution of your crystal): assuming a gaussian distribution of intensities around zero, we expect (100-99.73)/2 % = 0.135% of reflections to be less than -3*sigma, and another 0.135% to be larger than 3*sigma. For a useful resolution shell, however, the expected percentage of reflections with intensity less than -3*sigma would be much less. Thus, changing the cutoff (there is indeed a keyword for that - see XDSCONV documentation) would not matter much. | |||
By the way, SCALEPACK also uses a -3 sigma cutoff (see "SIGMA CUTOFF" at http://www.hkl-xray.com/hkl_web1/hkl/Scalepack_Keywords.html). | |||
== other questions == | == other questions == |