Crystallography
Crystallographic Theory
- Basics of Crystallography
- Phase problem, and Phasing
- Twinning
- R-factors
- [Bulk solvent correction]
- Fiber diffraction
- References and links
Crystallography Software
For Specific Tasks
- Data reduction
- Molecular replacement (MR)
- Substructure determination
- Experimental phasing (SIR/MIR and SAD/MAD)
- Electron density modification
- Automated Model building
- Interactive Model building
- Refinement
- Model validation
- Model Evaluation
Automated Pipelines for Structure Solution
- Ants
- Auto-Rickshaw (Structure determination)
- AutoSHARP
- BALBES
- BNP
- CRANK
- Elves
- MrBUMP - molecular replacement
- Phenix - comprehensive package
- HKL2MAP - SAD/MAD/SIRAS/SIR phasing based on SHELXC/D/E
Web services
- ARP/wARP web services (model building)
- Auto-Rickshaw (Structure determination) - see example at xds:1RQW
- Bias removal server
- York suite (Balbes, Modsearch, Zanuda)
- Diffraction Anisotropy Server
- Bravais Lattice Determination by Projections
Software Packages
(large packages first)
- CCP4
- CNS
- PHENIX
- SHELX C/D/E and SHELXL (homepage at [1], overview paper)
- moleman, lsqman, ... from Uppsala Software Factory
- XDS homepage and XDSwiki
- HKL homepage
- COOT
- PyMol wiki
- CCP4mg
- O
- ARP/wARP
- SHARP homepage
- Solve/Resolve
- ...
- Clipper
- Crystallographic Toolbox
- CCP4 library; documentation at [2]
- mmdb
Tricks and Tips
Teaching crystallography
Understanding and extending the properties and limitations of crystallographic computations
Ensemble refinement, and molecular dynamics
- Direct Observation of Protein Solvation and Discrete Disorder with Experimental Crystallographic Phases. Burling FT, Weis WI, Flaherty KM, Brünger AT. Science (1996) 271, 72-77 [3]
- Heterogeneity and Inaccuracy in Protein Structures Solved by X-Ray Crystallography. DePristo MA,de Bakker PIW, Blundell TL (2004) Structure 12, 831-838 [4]
- Ensemble Refinement of Protein Crystal Structures: Validation and Application. Levin EJ, Kondrashov DA, Wesenberg GE, Phillips GN, Structure 15, 1040 - 1052 [5]
- A comparison between molecular dynamics and X-ray results for dissociated CO in myoglobin. Vitkup D, Petsko GA, Karplus M. Nature Structural Biology 4, 202 - 208 (1997) [6] (Vitkup et al showed that fitting a single model to MD-simulation derived "data" gave ~20% R, which means multiple conformers are sufficient to explain the "R-Factor Gap" between the 20% usually obtained for macromolecules, and the 5% routinely obtained for small molecules)
Electron microscopy and X-ray
- Elucidating the medium-resolution structure of ribosomal particles: an interplay between electron cryo-microscopy and X-ray crystallography. Harms J, Tocilj A, Levin I, Agmon I, Stark H, Kölln I, van Heel M, Cuff M, Schlünzen F, Bashan A, Franceschi F, Yonath A. Structure 7, 931-941 (1999) [7]
NMR versus X-ray
A couple of papers analysing and comparing NMR and X-ray methods/structures:
- Combining experimental information from crystal and solution studies: joint X-ray and NMR refinement. Shaanan B, Gronenborn AM, Cohen GH, Gilliland GL, Veerapandian B, Davies DR, Clore GM. Science (1992), 257, 961 [8]
- X-ray Crystallography and NMR: Complementary Views of Structure and Dynamics, Nature Structural Biology 4, 862-865 (1997). Preprint available from Axel Brunger's "publications" website.
- Traditional Biomolecular Structure Determination by NMR Spectroscopy Allows for Major Errors. S.B. Nabuurs, C.A.E.M. Spronk, G.W. Vuister, G. Vriend. PLoS Comput Biol 2(2): e9. [9]